Overheating assessment
Part O of the Building Regulations requires new homes to be designed so they do not overheat in summer. You show compliance either with the simplified method or with a dynamic thermal model to CIBSE TM59.
This guide covers the rules in England. See Wales, Scotland and Northern Ireland.
- overheating assessors listed
- 72
- verified listings
- 12
- regulation or standard
- Part O
- region pages
- 11
72 overheating assessors listed across the UK
Featured (paid) listings first, then A–Z · How we check listings
London (26) South East (13) East of England (18) South West (16) West Midlands (13) East Midlands (12) Yorkshire and the Humber (12) North West (17) North East (7) Wales (8) Scotland (10)
National providers (46)
AES Sustainability Consultants
Based in Tiverton, Devon · Covers England, Scotland and WalesAssessment Hive
Based in Goffs Oak, Hertfordshire · Covers London and throughout the UKATSPACEVerified
Based in Royston, Hertfordshire · Covers England and WalesBase Energy
Based in Staines-upon-Thames, Surrey and Bootle, Merseyside · Covers UK-wide, including LondonBriary Energy
Based in Hatfield, Hertfordshire · Covers UK-wideBuilding Energy ExpertsVerified
Based in Bristol · Covers NationwideCarbon Futures
Based in Glasgow (also Edinburgh) · Covers Throughout the UK; projects concentrated in ScotlandComplete EPC
Based in Finchley, London · Covers All of London, and elsewhere in the UKE2 Specialist Consultants
Based in Birmingham office (head office Wakefield) · Covers Birmingham and 25+ West Midlands townsEasy EPC Ltd
Based in Brighton, East Sussex · Covers Nationwide, with local landing pages for many UK towns including Leicester, Nuneaton and CoventryElmstead Energy Assessments & Building Services (EEABS)
Based in Colchester, Essex · Covers UK-wide, including London Plan energy assessmentsEnergistVerified
Based in Cirencester, Gloucestershire · Covers NationwideEnergy & Design
Based in Cannock, Staffordshire · Covers England, Scotland and WalesEnergy Counsel
Based in Manchester, Greater Manchester · Covers Manchester, the North West and nationwideEnergy National
Based in Rochdale, Greater Manchester · Covers Greater Manchester and East Lancashire locally; SAP work nationwideEnergyWise Services
Based in Belfast, Northern Ireland · Covers UK-wide (remote delivery available)enevoVerified
Based in Birstall, West Yorkshire · Covers UK-wide (national network of local assessors)Environmental Economics
Based in Luton, Bedfordshire · Covers UK nationwide, including London Plan workEPC Experts
Based in Coventry, West Midlands · Covers Coventry, Nuneaton, Rugby, Warwick and nationwideExpert Energy Consultancy Ltd
Based in Sheffield, South Yorkshire · Covers Sheffield and Yorkshire; remote service UK-wideFocus 360 Energy
Based in UK (several offices) · Covers NationwideGradwell Group
Based in Doncaster, South Yorkshire · Covers England-wideHA AcousticsVerified
Based in Harlow, Essex · Covers East Anglia, London, South West and nationwideJPA M&E Consultants
Based in Edinburgh · Covers All regions, from Edinburgh, Newcastle and London officesMACH Acoustics
Based in Bristol · Covers Across the UK (Bristol and London contacts)Melin Energy ConsultantsVerified
Based in Swansea · Covers UK-wide (offices in Swansea, Bristol and London)MES Building Solutions
Based in Newark, Nottinghamshire · Covers Throughout the UK (offices in Newark, London and Birmingham)Purple Energy Solutions
Based in UK (several offices) · Covers NationwideQuinnRoss Energy
Based in Sittingbourne, Kent · Covers UK-wide, with a focus on Greater London and the South EastR P Compliance Testing Ltd
Based in Dersingham, Norfolk · Covers Nationwide (stated); East AngliaREDFANsolutions Ltd
Based in Not stated – check with provider · Covers England and Wales, incl. Conwy, Denbighshire and GwyneddSouthern Assessors
Based in Salisbury, Wiltshire · Covers UK-wide, with offices in London, Bristol and BirminghamStroma Built EnvironmentVerified
Based in Wakefield, West Yorkshire · Covers UK-wideSyntegra Consulting Ltd
Based in Reading, Berkshire · Covers UK-wideUK Building ComplianceVerified
Based in Hinckley, Leicestershire · Covers UK-wide (England, Wales, Scotland and Northern Ireland)UK Overheating
Based in Birmingham, West Midlands · Covers England, Wales and Scotland (UK-wide coverage stated)Vision Energy & Sustainability
Based in Bollington, Cheshire · Covers UK-wideRegional providers (check they cover your area) (1)
UKSAPS
Based in Royston, Hertfordshire · Coverage not stated, so check with the providerTwo ways to comply
Simplified method
Checks glazing areas, orientation, shading and how much the windows can open, based on whether the site is in a moderate- or high-risk location.
Dynamic modelling (TM59)
A computer model of the home through a hot summer. It is useful for larger windows, flats and higher-risk sites where the simplified method fails.
Design choices that help
- Keeping large glazed areas off south and west-facing walls, or shading them
- Windows that open wide enough for cross-ventilation
- Passive measures first, before relying on any mechanical cooling
In Wales, Scotland and Northern Ireland
This guide describes the rules in England. Building regulations are devolved, so here is how overheating assessment works in the rest of the UK.
Wales has its own Part O, in force since 23 November 2022. As in England, it covers new homes only, using the simplified method or TM59 modelling.
Standard 3.28 has required new homes to limit the risk of overheating since February 2023. The assessment goes in with the building warrant application, using either a simplified method or TM59 modelling.
There is no equivalent of Part O. Designers only need to show a basic check on solar gains as part of the SAP calculation.
Common questions
Does my extension need an overheating assessment?
No. Part O only applies to new residential buildings, not extensions, conservatories added later, or changes of use.
Which method should I use?
Try the simplified method first. If the design fails it, for example because of large glazing or a high-risk location, dynamic modelling gives more flexibility.
When is the assessment done?
At design stage, before building control approves the plans, so any changes to glazing, shading or window openings can still be made.
What design choices help a home pass?
Keeping large glazed areas off south and west-facing walls or shading them, windows that open wide enough for cross-ventilation, and passive measures before relying on any mechanical cooling.
Sources
The rules and dates in this guide were checked against these pages on 17 October 2026. They are independent of us and may change, so check the current version before you rely on it.
- Overheating: Approved Document O (GOV.UK)
- Approved Document O: overheating, frequently asked questions (GOV.UK)
New to the jargon? See our glossary of terms, from air permeability to TrustMark.