Water efficiency calculations
Every new home in England must be designed so that water use is no more than 125 litres per person per day. A water efficiency calculation shows building control that the taps, toilets, showers, baths and appliances you have chosen meet that limit.
This guide covers the rules in England. See Wales, Scotland and Northern Ireland.
- providers listed
- 77
- verified listings
- 16
- regulation or standard
- Part G
- region pages
- 11
77 providers listed across the UK
Featured (paid) listings first, then A–Z · How we check listings
London (23) South East (13) East of England (17) South West (14) West Midlands (15) East Midlands (11) Yorkshire and the Humber (11) North West (13) North East (6) Wales (10) Scotland (6)
National providers (50)
AES Sustainability Consultants
Based in Tiverton, Devon · Covers England, Scotland and WalesAir Tightness Solutions LtdVerified
Based in Wantage, Oxfordshire · Covers OxfordshireAirtight Testing StaffordshireVerified
Based in Stoke-on-Trent · Covers Staffordshire and UK-wideApex Home and Energy Surveyors
Based in Warrington, Cheshire · Covers Warrington and WA postcodes for EPCs; calculation work across England and WalesAPT Sound Testing (Air Pressure Testing Ltd)Verified
Based in Upper Sundon, Bedfordshire · Covers Coventry, Warwickshire and UK-wideAssessment Hive
Based in Goffs Oak, Hertfordshire · Covers London and throughout the UKATSPACEVerified
Based in Royston, Hertfordshire · Covers England and WalesBase Energy
Based in Staines-upon-Thames, Surrey and Bootle, Merseyside · Covers UK-wide, including LondonBriary Energy
Based in Hatfield, Hertfordshire · Covers UK-wideBuilding Energy ExpertsVerified
Based in Bristol · Covers NationwideComplete EPC
Based in Finchley, London · Covers All of London, and elsewhere in the UKCompliance 4 BuildingsVerified
Based in Hornchurch, Essex · Covers Nationwide (UK)Coventry Property Certification
Based in Coventry, West Midlands · Covers England and WalesE2 Specialist Consultants
Based in Birmingham office (head office Wakefield) · Covers Birmingham and 25+ West Midlands townsEasy EPC Ltd
Based in Brighton, East Sussex · Covers Nationwide, with local landing pages for many UK towns including Leicester, Nuneaton and CoventryElmstead Energy Assessments & Building Services (EEABS)
Based in Colchester, Essex · Covers UK-wide, including London Plan energy assessmentsEnergistVerified
Based in Cirencester, Gloucestershire · Covers NationwideEnergy & Design
Based in Cannock, Staffordshire · Covers England, Scotland and WalesEnergy Counsel
Based in Manchester, Greater Manchester · Covers Manchester, the North West and nationwideEnergy National
Based in Rochdale, Greater Manchester · Covers Greater Manchester and East Lancashire locally; SAP work nationwideEnergytest
Based in Tunbridge Wells, Kent · Covers London and the South East; nationwideenevoVerified
Based in Birstall, West Yorkshire · Covers UK-wide (national network of local assessors)Environmental Economics
Based in Luton, Bedfordshire · Covers UK nationwide, including London Plan workEPC Assess Ltd
Based in Midlands · Covers Birmingham, Wolverhampton, Coventry and UK-wideEPC Experts
Based in Coventry, West Midlands · Covers Coventry, Nuneaton, Rugby, Warwick and nationwideExpert Energy Consultancy Ltd
Based in Sheffield, South Yorkshire · Covers Sheffield and Yorkshire; remote service UK-wideFocus 360 Energy
Based in UK (several offices) · Covers NationwideGradwell Group
Based in Doncaster, South Yorkshire · Covers England-wideGreens Surveyors Ltd
Based in Bradford, West Yorkshire · Covers Nationwide (no regions named)HA AcousticsVerified
Based in Harlow, Essex · Covers East Anglia, London, South West and nationwideManchester EPC Ltd
Based in Cheadle, Greater Manchester · Covers EPC visits within about 50 miles of Manchester; SAP and new-build work nationwideMelin Energy ConsultantsVerified
Based in Swansea · Covers UK-wide (offices in Swansea, Bristol and London)MES Building Solutions
Based in Newark, Nottinghamshire · Covers Throughout the UK (offices in Newark, London and Birmingham)MSAFE
Based in Bournemouth, Dorset · Covers NationwidePurple Energy Solutions
Based in UK (several offices) · Covers NationwideQuinnRoss Energy
Based in Sittingbourne, Kent · Covers UK-wide, with a focus on Greater London and the South EastR P Compliance Testing Ltd
Based in Dersingham, Norfolk · Covers Nationwide (stated); East AngliaREDFANsolutions Ltd
Based in Not stated – check with provider · Covers England and Wales, incl. Conwy, Denbighshire and GwyneddSouthern Assessors
Based in Salisbury, Wiltshire · Covers UK-wide, with offices in London, Bristol and BirminghamStroma Built EnvironmentVerified
Based in Wakefield, West Yorkshire · Covers UK-wideUK Building ComplianceVerified
Based in Hinckley, Leicestershire · Covers UK-wide (England, Wales, Scotland and Northern Ireland)UK Overheating
Based in Birmingham, West Midlands · Covers England, Wales and Scotland (UK-wide coverage stated)Vision Energy & Sustainability
Based in Bollington, Cheshire · Covers UK-wideRegional providers (check they cover your area) (1)
UKSAPS
Based in Royston, Hertfordshire · Coverage not stated, so check with the providerThe two limits
- 125 litres per person per day: the standard Part G requirement.
- 110 litres per person per day: the optional tighter requirement, which applies when your planning permission includes a condition requiring it. Check your decision notice.
How it is worked out
The calculation uses the flow rates and capacities of the fittings you plan to install. You can also use the "fittings approach", which sets maximum flow rates for each fitting. Changing fittings during the build can affect compliance, so tell your assessor if the specification changes.
In Wales, Scotland and Northern Ireland
This guide describes the rules in England. Building regulations are devolved, so here is how water efficiency calculations works in the rest of the UK.
Wales is stricter than England. 110 litres per person per day is the standard limit for every new home, not an optional extra. Homes created by conversion have a 125 litre limit.
There is no per-person water calculation. Instead, new homes must use water-efficient fittings, such as toilets that use no more than 4.5 litres per flush and basin taps of no more than 6 litres a minute.
There is no water efficiency limit, so building control doesn’t need a water calculation.
Common questions
Does an extension need a water calculation?
No. The Part G water efficiency requirement applies to new homes.
What fittings make the biggest difference?
Toilets, showers and baths usually have the most effect. Dual-flush toilets and flow-restricted showers make the lower limits easier to meet.
What is the limit?
125 litres per person per day for a new home in England. A tighter limit of 110 litres applies when your planning permission includes a condition requiring it, so check your decision notice.
Who does the calculation, and when?
Usually your SAP assessor or designer, at design stage. It’s confirmed at completion if the fittings change, so tell your assessor about any changes to the specification.
Sources
The rules and dates in this guide were checked against these pages on 17 October 2026. They are independent of us and may change, so check the current version before you rely on it.
- The Building Regulations 2010, regulation 36: water efficiency of new dwellings (legislation.gov.uk)
- The Building Regulations 2010, regulation 5: meaning of material change of use (legislation.gov.uk)
- Sanitation, hot water safety and water efficiency: Approved Document G (GOV.UK)
New to the jargon? See our glossary of terms, from air permeability to TrustMark.